The Extron NetPA 1001‑70V AT is a half rack 1U, convection cooled power amplifier featuring Dante™. It delivers a single channel of 100 watts at 70 volts for high impedance speaker systems. The NetPA® amplifier receives a channel of audio from a Dante-enabled device, allowing for decentralized distribution of audio throughout a building. In addition to amplifying incoming Dante audio, the NetPA amplifier features a line level output that can simultaneously feed an additional speaker zone or audio system. It is an ENERGY STAR® qualified amplifier with an Extron exclusive, highly efficient, advanced Class D amplifier design. It also features patented CDRS™ – Class D Ripple Suppression that provides improved signal fidelity over conventional Class D amplifiers.


Audio
   Crosstalk  >75 dB @ 1 kHz
Audio input
   Number/signal type 
      NetPA 502 AT  1 stereo or 2 mono
      NetPA 1001-70V AT  1 mono
   Connectors  1 RJ-45
   Maximum level  0 dBFS (digital)
Audio processing
   D/A conversion  24 bit, selectable sampling rate
AT ports — audio transport
   Transmission  Dante/AES-67, software selectable
   Connector  1 RJ-45 connector, 1-port 100 Mbps to Dante interface
   Inputs 
      NetPA 502 AT  2 channels Rx
      NetPA 1001-70V AT  1 channel Rx
   Audio format  24-bit uncompressed, selectable at 44.1, 48, 88.2, and 96 kHz sampling rate
   Latency  Deterministic, based on user selection: 2.0 ms (default), 5.0 ms
Audio line output
   Number/signal type 
      NetPA 502 AT  2 channels, balanced/unbalanced
      NetPA 1001-70V AT  1 channel, balanced/unbalanced
   Connectors 
      NetPA 502 AT  (1) 3.5 mm captive screw connector, 6 pole
      NetPA 1001-70V AT  (1) 3.5 mm captive screw connector, 3 pole
   Impedance  50 ohms unbalanced, 100 ohms balanced
   Maximum level (at 0 dBFS digital input)  >+15 dBu balanced; +9 dBu unbalanced
   Frequency response  20 Hz to 20 kHz, ±1 dB
   THD + Noise  0.03% @ 1 kHz at nominal level,
0.3% @ 20 kHz at nominal level
   S/N  >90 dB, at maximum output (unweighted)
    NOTE     0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
Audio speaker output
   Number/signal type 
      NetPA 502 AT  2 channels, 4 or 8 ohms
      NetPA 1001-70V AT  1 channel, 70 V
   Connectors 
      NetPA 502 AT  (1) 5.08 mm screw lock captive screw connector, 4 pole
      NetPA 1001-70V AT  (1) 5.08 mm screw lock captive screw connector, 2 pole
    NOTE     These connectors accept wires of 22 AWG to 12 AWG.
   Load impedance 
      NetPA 502 AT  4 ohms minimum
      NetPA 1001-70V AT  50 ohms minimum
   Amplifier type  Class D
   Output power 
      NetPA 502 AT  50 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD
25 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD
      NetPA 1001-70V AT  100 watts rms, 70 V, 1 kHz, 0.1% THD
   Frequency response 
      NetPA 502 AT  20 Hz to 20 kHz, +1/-3 dB @ 1 watt
      NetPA 1001-70V AT  20 Hz to 20 kHz, +1/-3 dB @ 1 watt
   THD + Noise  <0.1% @ 1 kHz, 3 dB below clipping
   S/N  >90 dB, 20 Hz - 20 kHz, unweighted
   High pass filter 
      NetPA 1001-70V AT  80 Hz, 12 dB per octave rolloff for 70 V line output (switch selectable)
Communications — amplifier
   Control port  (1) 3.5 mm captive screw connector, 2 pole
   Pin configurations 
      Standby power control (contact closure) 

Pin 1 = standby, pin 2 = Gnd

General
   Power supply  Internal
Input: 100-240 VAC, 50-60 Hz, 0.5 A
   Power consumption and thermal dissipation 
      NetPA 502 AT
  115 VAC, 60Hz 230 VAC, 50Hz
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
AC Line
Current
AC Power
Consumed
Thermal
Dissipation/
Condition A W W BTU/hr A W W BTU/hr
Active (1/8 power), all
channels driven
0.3 14.6 8.3 28 0.2 17 10.7 36
0.4 22.3 9.8 33 0.3 24 11.7 40
Quiescent (idle) 0.1 7.4 7.4 25 0.1 9.9 9.9 34
Standby <0.1 <2 <2 <6 <0.1 <2 <2 <6

 

      NetPA 1001-70V AT
  115 VAC, 60Hz 230 VAC, 50Hz
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
Condition A W W BTU/hr A W W BTU/hr
Active (1/8 power), all
channels driven
70 V 0.4 22.7 10.2 35 0.3 24.1 11.6 39
Quiescent (idle) 0.1 7.6 7.6 26 0.1 9.2 9.2 31
Standby <0.1 <2 <2 <6 <0.1 <2 <2 <6

 

   Temperature/humidity  Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +104 °F (0 to +40 °C) / 10% to 90%, noncondensing
   Cooling  Convection, no vents, with internal heat sink
   Protection  Clip limiting, thermal, short circuit, DC output
   Indication  Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, or short circuit
   Mounting 
      Rack mount  Yes, with optional 1U rack shelf
      Furniture mount  Yes, with optional under-desk mounting kit
   Enclosure type  Metal
   Enclosure dimensions  1.7" H x 8.7" W x 9.5" D (1U high, half rack wide)
(4.3 cm H x 22.1 cm W x 24.1 cm D)
   Product weight 
      NetPA 502 AT  2.6 lbs (1.2 kg)
      NetPA 1001-70V AT  2.6 lbs (1.2 kg)
   Regulatory compliance  BSEN 60065, CE, C-tick, c-UL, EN 55103-1, EN 55103-2, ENERGY STAR®, 
FCC Class B, ICES, IEC 60065, RoHS, UL, UL 60065, VCCI Class B, WEEE.
   Product warranty  3 years parts and labor
   Everlast power supply warranty  7 years parts and labor
    NOTE     All nominal levels are at ±10%.
    NOTE     Specifications are subject to change without notice.
(4536-D8)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-1501-01 4.5" (11.4 cm) 13.75" (34.9 cm) 14.0" (35.6 cm) 5.0 lbs (2.27 kg)

 